PSS offers pumping systems for all GPC/SEC needs, providing excellent flow and composition stability over a wide range of flow rate ranges. Hardware and software of all SECcurity GPC1260 pumps are designed for easy setup, operation, maintenance and early recognition of problems. All pumps and degassers can be used also with difficult GPC/SEC solvents including hexafluoroisopropanol HFIP.

 

 

isocratic pump

P/N 404-0101

binary pump

P/N 404-0102

quaternary pump

P/N 404-0103

vacuum degasser 2 channels

P/N 409-0024

vacuum degasser 4 channels

P/N 409-0031

 

 

SECcurity isocratic pump

SECcurity 1260 isocratic pump

The ideal GPC/SEC pump with highest run-to-run and day-to-day precision of retention times. The optimized design ensures virtually pulse-free and stable solvent flow, with dual floating pistons in series, precisely servo-controlled. This delivery principle allows variable stroke volume optimized to selected flow rate. An inlet-valve electronically activated and synchronized to piston stroke - eliminates vapor formation with volatile solvent. Low operating and maintenance costs - due to long instrument uptime. Versatile wide flow range - up to 10 mL/min, including semi-preparative separations. Robust materials withstand most demanding applications - stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE ensure long lifetime. Seal wash option for high salt mobile phases keeps maintenance to a minimum for lower operation costs.

 

Specifications

Flow

Precision

≤0.07 % RSD,or ≤0.02 min SD whatever is greater, based on retention time at constant room temperature

Accuracy

± 1 % or 10 µL/min whatever is greater

Range

Setpoints from 0.001 to 10.0 mL/min,
in 0.001 mL/min increments

Pressure

Operating range

0 - 60 MPa (0 - 600 bar, 0 - 5880 psi) up to 5 mL/min
0 - 20 MPa (0 - 200 bar, 0 - 2950 psi) up to 10 mL/min

Pulsation

<2 % amplitude (typically <1 %) at 1 mL/min isopropanol at all pressures >1 MPa (> 10 bar, >147 psi)

Compress. compensation

User selectable, based on mobile phase compressibility

pH range

1.0 - 12.5
Solvents with pH <2.3 should not contain acids which attack steel

GLP/Compliance

Electronic records of maintenance and errors. Early maintenance feedback (EMF) for continuous tracking of instrument usage, display of feedback messages if preset limits are exceeded.

 

Part number: 404-0101
Option seal wash: 404-0116 
Request a quote and product information

SECcurity binary pump

SECcurity GPC1260 binary pump

The SECcurity binary pump is based on a high-pressure mixing principle. It is the pump of choice for reproducible gradients and high performance, especially at low flow rates and for high throughput applications. It has an optional programmable solvent selection valve which combines two out of four solvents for utmost flexibility and increased convenience, for example, when flushing the column. The binary pump is also ideally suited to do standard-bore chromatography. Floating pistons with path-of-least-resistance principle ensures highest seal lifetime.




Specifications

Flow

Precision

≤0.07 % RSD,or ≤0.02 min SD whatever is greater, based on retention time at constant room temperature

Accuracy

± 1 % or 10 µL/min whatever is greater

Range

Setpoints from 0.001 to 5.0 mL/min,
in 0.001 mL/min increments

Pressure

Operating range

0 - 60 MPa (0 - 600 bar, 0 - 5880 psi) up to 5 mL/min

Pulsation

<5 % amplitude (typically <2 %) at 1 mL/min isopropanol at all pressures > 1 MPa (10 bar)

Compress. compensation

User selectable, based on mobile phase compressibility

Gradient

Delay volume

Standard delay volume configuration:
600-800 µL, dependent on back pressure (includes 400 µL mixer)
Low delay volume configuration: 120 µL

Composition precision

<0.15 % RSD, 1 mL/min

Composition accuracy

<0.35 % absolute

pH range

1.0 - 12.5
Solvents with pH <2.3 should not contain acids which attack steel

GLP/Compliance

Electronic records of maintenance and errors. Early maintenance feedback (EMF) for continuous tracking of instrument usage, display of feedback messages if preset limits are exceeded.

 

Part number: 404-0102
Option seal wash: 404-0124 
Request a quote and product information

SECcurity quarternary pump

SECcurity GPC1260 quaternary pump

The SECcurity quaternary pump is a pump for low pressure mixing of up to four solvents. The quaternary pump provides highest flexibility in solvent mixing and is recommended for a wide range of research and routine applications, and in the method development area. It ensures virtually pulse-free and stable solvent flow, with dual floating pistons in series, precisely servo-controlled. The variable stroke volume allows pulse-free solvent delivery and efficient mixing. Keeps maintenance to a minimum for lower operation costs by using robust materials such as stainless steel, titanium, gold, ruby, sapphire, ceramics, PEEK and PTFE. Optional active seal wash option for high salt mobile phases to prevent corrosion. Wide flow range of up to 10 mL/min, including semi-preparative separations.

 

Specifications

Flow

Precision

≤0.07 % RSD,or ≤0.02 min SD whatever is greater, based on retention time at constant room temperature

Accuracy

± 1 % or 10 µL/min whatever is greater

Range

Setpoints from 0.001 to 10.0 mL/min,
in 0.001 mL/min increments

Pressure

Operating range

0 - 40 MPa (0 - 400 bar, 0 - 5880 psi) up to 5 mL/min
0 - 20 MPa (0 - 200 bar, 0 - 2950 psi) up to 10 ml/min

Pulsation

<2 % amplitude (typically <1.3 %) at 1 mL/min isopropanol at all pressures >1 MPa (> 10 bar, >147 psi)

Compress. compensation

User selectable, based on mobile phase compressibility

Gradient

Delay volume

800 - 1100 µL depending on back pressure

Composition precision

<0.20 % SD, at 0.2 and 1 mL/min

pH range

1.0 - 12.5
Solvents with pH <2.3 should not contain acids which attack steel

GLP/Compliance

Electronic records of maintenance and errors. Early maintenance feedback (EMF) for continuous tracking of instrument usage, display of feedback messages if preset limits are exceeded.

 

Part number: 404-0103
Request a quote and product information

SECcurity vacuum degasser

SECcurity vacuum degassers with four and two independent channels

Special on-line vacuum degasser for all GPC/SEC eluents including hexafluoroisopropanol HFIP. The degasser has two, three, or four independent  solvent channels with a small volume for optimum degassing up to a flowrate of 3 ml/min. The two (three) channel degasser is modular upgradable to add additional independent solvent channels.

 

Specifications

Number of Channels

2, 3, 4

Internal Channel Volume

480 ml

wetted parts

PEEK, Teflon AF®

Life expectancy

5 years continous run

GLP/Compliance

validation analog out 5 mVDC / 1 mm Hg ±1.0%

 

Part numbers:

2 channel degasser: 409-0024

4 channel degasser: 409-0031
Request a quote and product information





< Back to LC Intruments and Detectors