SECcurity GPC/SEC detectors

The PSS SECcurity GPC1260 system can be equipped with a single detector or any detector combination needed for modern hyphenated macromolecular characterization techniques.

 

Refractive Index RI   

P/N 404-0106

Evaporative light scattering detector ELS1400              

P/N 409-0032

Variable wavelength UV-VIS

P/N 404-0107

Multiple wavelength UV-VIS                                            

P/N 404-0108

Diode Array Detector (DAD)

P/N 404-0110

on-line multi angle light scattering detector SLD7000

P/N 403-0001

on-line viscometer ETA2010

P/N 402-0001

 

 

                                               

 

 

SECcurity GPC1260 Refractive Index RI detector

SECcurity GPC1260 RI detector

The detector of  choice for the analysis of non-UV absorbing samples. Ideal concentration detector for the combination with on-line light scatterging detectors or on-line viscometers. High signal-to-noise ratio is enabled by a minimum baseline noise. Electronic temperature regulation maintains a steady optical unit temperature up to 55° C. Convenient early maintenance feedback (EMF) is available. An automatic solvent recycle valve is already included. 

 

Specficications

Detection type

Deflection mode 

Short-term noise

± 2.5 x 10-9 RIU

Drift

200 x 10-9 RIU/h

Refractive index range

1.00–1.75, calibrated

Flow cell

8 µL, 5 bar pressure maximum

Temperature control

Ambient +5 °C to 55 °C

pH range

2.3 - 9.5

Time programmable

Polarity, peak width

Zero adjustment

Automatic zero

Valves

Automatic purge and automatic solvent recycle

Analog output

Recorder/integrator: 100 mV or 1 V, with offset adjustment, RIU range selectable

GLP/Compliance

Early maintenance feedback (EMF) for continuous tracking of instrument usage with user-settable limits (purge interval) and feedback messages. Electronic records of maintenance and errors, automated OQ/PV procedures.


Part number: 404-0106
Request a quote and product information

 

SECcurity Evaporative light scattering detector ELS1400

SECcurity GPC1260 ELS detector

ELSD with superior and sensitive detection for a wide variety of chemical classes and structures. With ThermoSplit technology for the optimal signal to noise ratio. Low detection limits down to 5 ng. Low evaporation temperatures and outstanding reproducibility. No baseline shift even with extreme gradients.

The fully warranted Teflon nebulizer provides superior solvent and chemical resistance, eliminates sample build-up even at high temperatures, does not permit sample carry over or increased noise from surface leaching. Reproducible droplet distributions are assured by thermally isolating the nebulizer from the spray chamber and drift tube, improving reproducibility between methods.


Low gas pressure and flow requirements allows use of cylinder,

house systems, or gas generators. The pneumatic system is protected

by a high pressure shut off, and provides a signal in the event of

unstable or low pressure.

 

Specifications

Detector type

Evaporative light scattering detector with Thermo-Split 

Evaporative Zone Temperature

25° C - 120° C

Thermo-Split™ Chamber Temperature

10° C - 60° C

Light source

670 nm laser diode, <5 mW

Flow rate

0.2 ml/min to 5 ml/min

Detection limit

5 ng

gas requirements

4 - 5,5 bar (60 - 80 psi) nitrogen or other inert gas

Analog output

0 - 1 VDC



Part number: 409-0032
Request a quote and product information

SECcurity Variable wavelength UV-VIS

SECcurity GPC1260 Variable Wavelength Detector

The SECcurity GPC1260 variable wavelength detector (VWD) lowers detection limits with simplified optics for high sensitivity, low baseline drift and wide linear range. Achieve high sensitivity and low detection limits with low baseline noise and drift. Cut operating costs with automatic shutdown for longer productive lamp lifetime.

 

Specifications

Detection type

Double-beam photometer

Light source

Deuterium lamp

Maximum data rate

80 Hz

Noise

± 0.25 x 10 -5 AU, at 230 nm

Drift

1 x 10-4AU/hr, at 230 nm

Linearity

>2.5 AU upper limit

Wavelength range

190-600 nm

Wavelength accuracy

± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter

Wavelength bandwidth

6.5 nm typical over whole wavelength range

Flow cells

Standard: 14-µL volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
High Pressure: 14-µL volume, 10-mm cell path length and 400 bar (5880 psi) Pressure maximum
Micro: 1-µL volume, 5-mm cell path length and 40 bar (588 psi) pressure maximum
Semimicro: 5-µL volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum

Analog output

Recorder/integrator 100 mV or 1 V

GLP/Compliance

Electronic records of maintenance and errors. Early maintenance feedback (EMF) for continuous tracking of instrument usage, display of feedback messages if preset limits are exceeded. Verification of wavelength accuracy with built-in holmium oxide filter.

 

Part number: 404-0107
Request a quote and product information

SECcurity Multiple wavelength UV-VIS

SECcurity GPC1260 Multiple Wavelength Detector

The SECcurity GPC1260 MWD is a dedicated multiple wavelength detector that offers the same high sensitivity for both single and multiple wavelength detection. Diode array design enables simultaneous acquisition of up to 8 compound-specific wavelengths for increased sensitivity and selectivity. Deuterium and tungsten lamps with a wavelength range of 190 to 950 nm offer an expanded detection range with lowest detection limit.

 

Specifications

Detector type

1024-element diode array

Light source

Deuterium and tungsten lamp

Number of signals

8

Maximum sampling rate

80 Hz

Short-term noise

± 0.6 x 10 -5 AU at 254 nm and at 750 nm

Drift

0.9 x 10 -3 mAU/h at 254 nm

Linearity

>2 AU (5 %) at 265 nm

Wavelength range

190-950 nm

Wavelength accuracy

± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter

Flow cells

standard: 13-µL volume, 10 mm-cell path length, 120 bar (1760 psi) pressure maximum

micro: 2-µL, volume, 3-mm cell path length, 400 bar (5880 psi) pressure maximum

preparative: 3-mm cell path length, 120 bar (1760 psi) pressure maximum
0.3-mm cell path lenght, 20 bar (294 psi) pressure maximum, quartz
0.06-mm cell path length, 20 bar (294 psi) pressure maximum, quartz

others on request

Analog output

Recorder/integrator 100 mV or 1 V, 2 outputs

GLP/Compliance

Electronic records of maintenance and errors. Early maintenance feedback (EMF) for continuous tracking of instrument usage, display of feedback messages if preset limits are exceeded. Verification of wavelength accuracy with built-in holmium oxide filter.

 

 

Part number: 404-0108
Request a quote and product information

SECcurity Diode Array Detector (DAD)

SECcurity GPC1260 Diode Array Detector

The SECcurity GPC1260 DAD features a completely new optical design based on the Agilent Max-Light cartridge cell with optofluidic waveguides. It enables scientist to reach lower detection limits, even under harsh and fluctuating ambient temperature and humidity conditions. Multiple wavelength and full spectral detection with up to 80 Hz data rates allows precise identification, quantification and purity analysis at trace levels .

 

Specifications

Detector type

1024-element diode array

Light source

Deuterium and tungsten lamp

Number of signals

8

Short-term noise

< ± 0.7 x 10 -5 AU at 254/4 nm and at 750 nm, TC 2sec.

Drift

< 0.9 x 10 -3 AU/h at 254 nm

Linearity

> 2.0 AU (5 %) at 265 nm

Wavelength range

190-950 nm

Wavelength accuracy

± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter

Flow cells

Standard:
13-µL volume, 10 mm-cell path length, 120 bar (1740 psi) pressure maximum</font><//font>

others on request

Analog output

Recorder/integrator 100 mV or 1 V, 2 outputs

GLP/Compliance

Electronic records of maintenance and errors. Early maintenance feedback (EMF) for continuous tracking of instrument usage, display of feedback messages if preset limits are exceeded. Verification of wavelength accuracy with built-in holmium oxide filter.

 

 

Part number: 404-0110
Request a quote and product information

SECcurity on-line multi angle light scattering detector SLD7000

SECcurity 7-angle MALLS on-line and off-line light scattering detector

The SECcurity SLD7000 MALLS is a 7-angle static light scattering detector for the measurement of absolute molecular weight, size, and conformation of macromolecules in solution. The revolutionary design with a cylindrical, self-cleaning, and index-matching cell avoids common pitfalls in GPC/SEC-light scattering detection. Modern ultra-sensitive CCD detection results in high sensitivity, even at low concentration and molar masses.

The small footprint allows integration into any GPC/SEC or FFF system.

The SLD7000 can be used in batch mode (off-line) without modifications.

 

 

 

Specifications

Number of angles

7 plus additional reference, simultaneous detection 

Detection angles/scattering angles

35, 50, 75, 90 105, 130, 145

no difference detection angle/scattering angle due to index-matching cell

Cell

PEEK

Cell volume

100 µL nominal

Scattering volume

20 nL nominal

Cell cleaning option

self cleaning cell with vertical flow path

Light source

35 mW, 635 nm, vertically polarized

temperature stabilized with precision power control

Detector

fibre optics with low numerical aperture, integral to cell

CCD with ultra-high sensitivity and spatial uniformity

Control

Integrated, dedicated, powerful microcontroller

Input

4 analog ins with 16 and 24 bit resolution for any concentration detector or viscometer

autosampler/manual injector digital inject in

Options

temperature control P/N 403-0005

other cell material on request

IR laser or different laser wavelength on request

15 additional analog channels on request

Software for static light scattering measurements in batch mode P/N 403-0004

GLP/Compliance

fan on/off with built-in temperature control

 

 

Part number: 403-0001

Software for off-line MALLS: Part number: 403-0004
Request a quote and product information

SECcurity on-line viscometer ETA2010

SECcurity ETA2010 on-line viscometer

The SECcurity ETA2010 viscometer four capillary viscometer lowers the detection limit with an asymmetric bridge design. While other viscometers dilute 50% of the sample in the solvent path, the ETA2010 dilutes only 20% of the sample in the solvent path. 80% of the sample run through the sample path leading to an unparalleled signal/noise ratio without any digital signal processing. Low-noise electronics combined with high-sensitivity pressure transducers results in excellent peak shapes and high signal linearity. The ETA2010 can be used with any GPC/SEC system. The use of reservoirs in the bridge eliminate viscometer modifications when the column setup changes and reduces the analysis time to 50% compared with other viscometers.

 


The SECcurity ETA2010 can be integrated into any GPC/SEC or FFF system.

 

Specifications

Detection type

4 capillary on-line viscometer

Signals

simultaneous measurement delta pressure and inlet pressure 

Noise level

0,2 Pa, diff. pressure channel, 25° C

Cell

asymmetric bridge with 80/20 split

Pressure transducers

fast-responding Hastelloy pressure transducers without hysteresis

Temperature range

ambient to 80° C, high temperature model to 150° C

Temperature stability

> 0.01° C

Temperature accuracy

± 0.5° C

Maximum flow rate

1.2 mL

Analog in

2 analog ins for any concentration detector

Start, Error, Flush, Zero

Analog output

1.0 Volt/10 kPa FSD Differential Pressure
1.0 Volt/100 kPa FSD Inlet Pressure

GLP/Compliance

Internal error logbook, electronic pressure transducer protection with error code

 

Part number: 402-0001
Request a quote and product information

 

< Back to LC Intruments and Detectors

Search


Training dates 2012

GPC/SEC training courses and educational webinarsmore

WinGPC UniChrom + ChromPilot released

New GPC/SEC software with controls for PSS, Agilent, Shimadzu, Dionex and moremore

European Reference Materials (ERM)/ Certified Reference Materials (CRM)

highly characterized polymers certified by BAMmore