GPC/SEC HighSpeed Columns

The PSS HighSpeed family of columns permits dramatic reductions in GPC analysis time, for polymers > 2000 Da without loss in resolution, accuracy or reproducibility. PSS HighSpeed columns have a larger diameter and a shorter length (20mm x 50mm) than their typical analytical counterparts (8mm x 300mm), and the ability to operate at optimum flow rates of 6.25 ml/min while keeping same linear flow, equal resolution and polymer information: Mw, Mn, Mp and PDI.

 

HigSpeed columns have unparalleled ability to produce a 12 point calibration curve in less than ten minutes; (Polystyrene 374 to 2 570 000 Da shown below). Optimum column design helps expedite product screening, process control,

and rapid sample throughput.

 

These columns can substitute the analytical columns without modifications to your LC system, as long as your pump and detectors can accommodate 6.25 ml/min. At this flow rate, you will use the same amount of solvent you currently use, but your elution occurs quicker.

 

HighSpeed columns are available with different column materials, particle sizes, and porosities, as linear and as single porosity columns.  

Calibration with Poly(styrene) ReadyCals green, red, and white: cocktails of 4 different molecular weight standards

Conditions

ColumnPSS SDV 5µ linear M, HighSpeed column
Stationary phaseadjusted for high pore volume and resolution
Flow rate, Time consumption6.25 ml/min, 7 minutes for THREE SAMPLES
Eluent, Eluent consumptionTHF, 44 ml for THREE SAMPLES
Temperature25 °C
DetectionGPC1100 RI
SamplesPSS Poly(styrene) ReadyCal green, red, white
Injection interval2.1 minutes (13.5 ml, overlaid injection not used)
Injection volume30 µL

 

 

Application example

A HighSpeed column (red line) reduces the run time for a sample (broad Poly(styrene)) by a factor of 6 - 8 compared to a conventional column (black line).

 

 

< Back to GPC/SEC columns - Powerful Solutions for Size Separation

 

Search


Career opportunities

New Employment Opportunities in Mainz, Germany more

Get your free column selection wall poster

PSS has released a wall poster for column selction in GPC/SEC.more

Polefin HT-GPC Columns

For HT-GPC separations, applicable wíth light scattering detectorsmore